Sök:

Sökresultat:

2739 Uppsatser om Wastewater treatment plant - Sida 1 av 183

Älgarås avloppsreningsverk- studie och metodisk felsökning av en biobädds BOD-rening

Wastewater contains biodegradable materials, which are often measured as BOD7.Trickling filters are sometimes used as a purification step for BOD-reduction. Atrickling filter is a tower, which is filled with a carrier material. Microorganisms growon the carrier material in the form of a biofilm. This biofilm consists mostly of bacteriathat purify water from BOD.In Älgarås? Wastewater treatment plant the water is purified by a trickling filter.However the treatment plant has difficulties reaching the emission requirements forBOD.

Membranbioreaktorteknik- en framtida lösning på Lundåkraverket? : Membrane bioreactors- A future solution at Lundåkra wastewater treatment plant?

Membrane bioreactors (MBR) combined with biological phosphorous treatment (Bio-P) has been investigated if that could be an alternative to the future expansion with conventional active sludge treatment at Lundåkra Wastewater treatment plant (WWTP) in the proximity of Landskrona, Sweden.The results showed that the surface demand in the biological treatment will be reduced with 67% with the MBR-alternative compared to a conventional activated sludge process. The nutrient removal in the MBR-solution was decreased or unchanged for nitrogen-, phosphorous- and organic parameters. However, the energy demand will increase with an estimated cost of approximately 1 million SEK annually. Moreover, the extra chemical consumption is estimated to cost 370 000 SEK annually.The disturbances caused by filamentous bacteria such as sludge dispersal could be resolved with MBR-technology because the membranes are not affected by these organisms. The Bio-P process combined with MBR-technology works if the wastewater recirculates from the membranes to an aerobic zone.In the proposal, there will be a new pre-treatment step, for instance hole screens.

Beräkningsmodell för massbalanser för Slottshagens reningsverk

In the next few years the pollutants loading at the Slottshagen Wastewater treatment plant in Norrköping is going to increase due to the reason that one of the waste water treatment plant in the district will be shut down.A survey of how these different pollutants are divided in the treatment process is therefore necessary for mapping out both the loading and treatment efficiency.This can be achieved by studying mass balances.Mass balances were carried out for the water treatment process for the mechanical/chemical,biological and the chemical stage.The mass balance studies show that the treatment efficiency was very good. However in order for the mass balances to be quite consistent and to ensure complete coverage of results and conclusions i.e. more reliable results, sludge samples should be collected and taken at different times per day and the influent rate should be investigated.In this work mass balance has been set up in order to illustrate and identify the factors that should be considered and taken care of for further estimation using mass balances in the future. Furthermore this survey results in a calculating model for the mass balances at thisplant.This calculating model is used as a tool to facilitate future calculations for mass balances for the water treatment process at Slottshagens Wastewater treatment plant.Moreover it provides a basis for carrying out further estimation of the treatment process in the near future.In this project the importance of some operating parameters was also taken in consideration.This calculating model can be modified so that calculations of such operating parameters i.e. sludge loading and sludge age can be easily performed.Such information can be used further to evaluate different operation alternative in order to ensure an optimal use of the treatment process with in the plant..

Förstudie till våtmark i Rimbo : Design för optimal hydrologi och kväverening

The euthropthication of the Baltic Sea is a threat that is beginning to be taken seriously by the governments concerned. In Sweden, regulations concerning the allowed nitrogen (N) concentration in the effluent water from Wastewater treatment plants are being tightened up. The Rimbo Wastewater treatment plant has been imposed to reduce the annual mean concentration of total N in the effluent water to levels below 15 mg l-1. A more and more common way to reduce the nitrogen level in wastewater is to let the water pass through a wetland. This study investigates the possibility to build this kind of wetland at the outlet of the Rimbo Wastewater treatment plant.A prestudy of the topography, soil characteristics and groundwater flow indicates that the land area in question is well suited for the construction of a wetland.

Total organic carbon (TOC) and chemical oxygen demand (COD) - Monitoring of organic pollutants in wastewater

Total organic carbon (TOC) and chemical oxygen demand (COD) are two methods used for measuring organic pollutants in wastewater. Both methods are widely used but the COD method results in production of hazardous wastes, including mercury.The purpose of this study was to validate the method TOC that will replace COD and find a factor to convert TOC to COD. In this study 26 samples were analyzed from four sewage treatment plant in the municipality of Enköping.The results show that the COD method could be replaced by the TOC method.The factor for COD/TOC was between 3.1 - 3.3. Both methods will be used in parallel until 2013 when it will be forbidden to use the COD analysis..

Kemisk karaktärisering samt nedbrytning av process- och avloppsvatten vid SCA Ortvikens pappersbruk

During pulp and papermaking process a huge amount of water is used. The wastewater contains a large amount of pollutants and has to be treated before it reaches the recipient. In March 2004 a new bleaching plant was started up at SCA Graphic Sundsvall AB, Ortviken?s paper mill using peroxide. The production of bleached thermo mechanical pulp and thus the load to the wastewater plant increased.

Föroreningsspridning via ledningsgravar : en fältstudie på Köpmanholmens industriområde

Sewer trenches usually contain material with a higher hydraulic conductivity then the adjacent soil. Thus they can serve as paths of preferential flow in a polluted area. Wastewater from factories can also leak from wastewater pipes and pollute the soil in the sewer trenches.The purpose of this project was to investigate pollutions in sewer trenches and in sewer pipes in the industrial area of Köpmanholmen, 20 km south of Örnsköldsvik in the north of Sweden. To make an estimation concerning the potential of transport of pollutions in sewer trenches, hydrological calculations were performed.Leakage to any greater extent did not seem to be a problem in the area. This is the case both for the concrete and the wooden pipes that have served as factory wastewater pipes.

Systemidentifiering och reglering av en luftningsbassäng på ett reningsverk

A Wastewater treatment plant has the task to refine the wastewater from substances that should not be released into the environment. The decomposition process can, in a simple way, be described as follows: micro-organisms breathe oxygen and eat unwanted substances. The environment in which the micro-organism lives is known as sludge and the correct amount of oxygen available in the sludge is important for the decomposition to be effective. The oxygenation of the sludge alone stands for about 30% of the plant?s energy consumption.

Anaerob rening vid StoraEnso Skoghalls Bruk

An analysis of a specific application of anaerobic wastewater treatment at a pulp and board mill, Stora Enso Skoghall, was carried out. A literature study was done and effluent wastewater from CTMP pulp production was analyzed. The analysis consisted of a broad constituent analysis and an anaerobic treatment trial. Results from these test where used to calculate the treatment effectiveness and resulting energy potential at the mill.The literature study and constituent analysis showed that toxicity of the water to be treated, due to wood extractives and sulphur content, was of concern. Detoxification chemicals targeting these constituents where used in the anaerobic treatment trial.

Återvinning av näringsämnen från hushållsspillvatten med omvänd osmos

Hammarby Sjöstad is a new district in Stockholm with high environmental standard. Stockholm Water Company evaluates a local Wastewater treatment plant with cutting edge technology. The first step is an experimental treatment plant (Sjöstadsverket) with four parallel lines of treatment, each with a capacity to treat wastewater from 150 persons. Within the membrane technology subproject the possibility of using reverse osmosis (usually called RO) to regain nutrients is examined.Reverse osmosis separates the incoming water in a clean permeate and a concentrate that, as the name indicates, is a more concentrated version of the incoming water. Using this method in wastewater treatment, a solution high in nutrients can be obtained without the use of chemical precipitation agent and with no production of sludge.

Utvärdering av anaerob behandling av hushållsspillvatten och tekniker för efterbehandling

The continuous process of urbanization results in demands on research and development for ecological and sustainable city development. Because of this, the current systems for wastewater treatment may have to be improved. In order to evaluate new technologies for municipal wastewater treatment, a development project has been initiated for the new district Hammarby Sjöstad in Stockholm. The project is lead by the company Stockholm Water. High environmental standards have been put up for the district, as it must be twice as good as an ordinary new district.

Vindpark Vänern : Fundamentteknik och Logistik

An analysis of a specific application of anaerobic wastewater treatment at a pulp and board mill, Stora Enso Skoghall, was carried out. A literature study was done and effluent wastewater from CTMP pulp production was analyzed. The analysis consisted of a broad constituent analysis and an anaerobic treatment trial. Results from these test where used to calculate the treatment effectiveness and resulting energy potential at the mill.The literature study and constituent analysis showed that toxicity of the water to be treated, due to wood extractives and sulphur content, was of concern. Detoxification chemicals targeting these constituents where used in the anaerobic treatment trial.

Analys av framtidens system för hantering av avloppsvatten och matavfall i Eskilstuna

Wastewater treatment is increasingly controlled by the Swedish environmental quality objectives, adopted by the Swedish parliament. There is a need for a sewage system that can fulfill stringent requirements concerning the environment, recycling and resource use and hygiene. Additional environmental aspects in recent years are the impact of climate change, new knowledge about the effects of pharmaceuticals in water, the need for improved wastewater treatment and increased recycling of nutrients to agriculture. This report has, from a future scenario of the year 2050, analyzed seven different systems for wastewater treatment and treatment of compostable biowaste from households in Eskilstuna. A future scenario was chosen based on that within a forty year period new challenges may arise which can result in higher demands on sewage treatment than those we see today. Another reason why the future scenario was established is that changes in wastewater treatment systems are slow to establish. The analysis is mainly focused on the economical aspects but environmental aspects such as emissions to receiving waters and potential recycling of plant nutrients has also been evaluated briefly.

Kraven på ägare till minireningsverk skiljer sig åt mellan olika kommuner

Discharge of inadequately treated waste water containing nutrients such as phosphorus and nitrogen as well as organic matter and bacteria is associated with a risk of eutrophication and contamination. The Swedish government has decided upon several Environmental Quality Objectives aiming to reduce the emissions of nutrients to water bodies.In Sweden, there are between 675 000 to 1 000 000 on-site sewage systems. Recent studies have shown that the function of small sewage treatment plants is in many cases insufficient. To prevent this regular service and supervision by a professional is needed. The focus of this study are small sewage treatment plants which use a technique where mechanical, chemical and/or biological reduction of pollutants is being used in the same facility to reduce nutrients in household wastewater.The aim of the study is to investigate how different municipalities ensure that small sewage treatment plants fulfill the requirements and reduce pollutants as efficient as the manufacturers claim.

Framtidens avloppsvattenreningsverk ? en modern energiproducent : En fallstudie av Himmerfja?rdsverket

In a sustainable society the use of renewable energy and recycling of materials is of high importance. Wastewater treatment plants use large amounts of energy in the processing of wastewater. This study seeks to evaluate wastewater as an energy resource and to examine treatment plants potential to become sustainable energy producers. The study is based upon the internal processes of Himmerfja?rdsverket.

1 Nästa sida ->